| Tipe | Indikator teknis | |||||
| Output | Tegangan DC | 5V | 12V | 24V | 36V | 48V |
| Arus sing dirating | 6A | 2.9A | 1.45A | 0.97A | 0.73A | |
| Daya sing dirating | 30W | 34.8W | 34.8W | 34.92W | 35.04W | |
| Riak lan swara | <75mVp-p | <120mVp-p | <150mVp-p | <240mVp-p | <240mVp-p | |
| Rentang pengaturan tegangan | ±10% | |||||
| Presisi voltase | ±2.0% | ±1.0% | ||||
| Tingkat pangaturan linier | ±0,5% | |||||
| Tingkat regulasi beban | ±1,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
| Masukan | Rentang/frekuensi voltase | 85-264VAC 47Hz-63Hz (120VDC~370VDC) | ||||
| Efisiensi (biasane) | 75% | 82% | 84% | 84,00% | 84% | |
| Arus kerja | <0.75A 110VAC <0.35A 220VAC | |||||
| Arus kejut | 110VAC 18A, 220VAC 36A | |||||
| Wektu miwiti | 200ms, 50ms, 20ms; 220VAC | |||||
| Karakteristik pangayoman | Proteksi beban sing berlebihan | ≥105%-150%; Output arus konstan +VO mudhun menyang titik tekanan ngisor, output cut off direset: daya maneh | ||||
| Proteksi sirkuit cendhak | +VO mudhun menyang titik tekanan ngisor kanggo nutup output | |||||
| Ilmu lingkungan | Suhu lan kelembapan kerja | -10ºC~+50ºC;20%~90RH | ||||
| Suhu lan kelembapan panyimpenan | -20ºC~+85ºC; 10%~95RH | |||||
| Keamanan | Resistensi tekanan | Input – output :1.5KVAC input-case :1.5KVAC output -case: 0.5kvac durasi :1 menit | ||||
| arus bocor | Input-output 1.5KVAC <5mA | |||||
| arus bocor | Input-output 220VAC <1mA | |||||
| Impedansi insulasi | Input-output lan input-shell, output-shell: 500 VDC/100mΩ | |||||
| Liyane | Ukuran | 129*98*38mm (P * L * T) | ||||
| Bobot bersih / bobot kotor | 342.6g/372.8g | |||||
| Cathetan | (1) Pangukuran riak lan gangguan: Nggunakake jalur pasangan bengkong 12 “kanthi kapasitor 0.1uF lan 47uF paralel ing terminal, pangukuran ditindakake ing bandwidth 20MHz. | |||||
| (2) Efisiensi diuji ing voltase input 230VAC, beban terukur lan suhu sekitar 25ºC. Akurasi: kalebu kesalahan setelan, laju penyesuaian linier lan laju penyesuaian beban. Cara uji laju penyesuaian linier: uji saka voltase endhek nganti voltase dhuwur ing beban terukur. Cara uji laju penyesuaian beban: saka beban terukur 0%-100%. Wektu wiwitan diukur ing kahanan wiwitan adhem, lan mesin saklar sing kerep cepet bisa nambah wektu wiwitan. Nalika dhuwure luwih saka 2000 meter, suhu operasi kudu dikurangi 5/1000. | ||||||