CJ:Kode perusahaan
M: Pemutus sirkuit kasus cetakan
1: Desain No
□: Arus sing dirating saka pigura
□: Kode karakteristik kapasitas pemecah/S nuduhake jinis standar (S bisa diilangi) H nuduhake jinis sing luwih dhuwur
Cathetan: Ana patang jinis kutub netral (kutub N) kanggo produk patang fase. Kutub netral tipe A ora dilengkapi elemen tripping arus berlebih, tansah diuripake, lan ora diuripake utawa dipateni bebarengan karo telung kutub liyane.
Kutub netral tipe B ora dilengkapi elemen tripping arus berlebih, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni). Kutub netral tipe C dilengkapi elemen tripping arus berlebih, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni). Kutub netral tipe D dilengkapi elemen tripping arus berlebih, mesthi diuripake lan ora diuripake utawa dipateni bebarengan karo telung kutub liyane.
| Jeneng aksesoris | Rilis elektronik | Pelepasan senyawa | ||||||
| Kontak bantu, ing ngisor voltase rilis, kontak alam | 287 | 378 | ||||||
| Rong set kontak bantu, kontak alarm | 268 | 368 | ||||||
| Pelepasan shunt, kontak alarm, kontak bantu | 238 | 348 | ||||||
| Ing ngisor voltase rilis, kontak alarm | 248 | 338 | ||||||
| Kontak bantu kontak alarm | 228 | 328 | ||||||
| Kontak alarm pelepasan shunt | 218 | 318 | ||||||
| Kontak bantu sing ora bisa dilepasake voltasene | 270 | 370 | ||||||
| Rong set kontak bantu | 260 | 360 | ||||||
| Pelepasan shunt ing ngisor voltase | 250 | 350 | ||||||
| Kontak bantu pelepasan shunt | 240 | 340 | ||||||
| Pelepasan voltase kurang | 230 | 330 | ||||||
| Kontak bantu | 220 | 320 | ||||||
| Pelepasan shunt | 210 | 310 | ||||||
| Kontak alarm | 208 | 308 | ||||||
| Ora ana aksesoris | 200 | 300 | ||||||
| 1 Nilai sing dirating saka pemutus sirkuit | ||||||||
| Model | Imax (A) | Spesifikasi (A) | Tegangan Operasi sing Dirating (V) | Tegangan Isolasi sing Dirating (V) | Icu (kA) | Ic (kA) | Cacahing Kutub (P) | Jarak Lengkung (mm) |
| CJMM1-63S | 63 | 6,10,16,20 25,32,40, 50,63 | 400 | 500 | 10* | 5* | 3 | ≤50 |
| CJMM1-63H | 63 | 400 | 500 | 15* | 10* | 3,4 | ||
| CJMM1-100S | 100 | 16,20,25,32 40,50,63, 80.100 | 690 | 800 | 35/10 | 22/5 | 3 | ≤50 |
| CJMM1-100H | 100 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-225S | 225 | 100,125, 160,180, 200.225 | 690 | 800 | 35/10 | 25/5 | 3 | ≤50 |
| CJMM1-225H | 225 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-400S | 400 | 225.250, 315.350, 400 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-400H | 400 | 400 | 800 | 65 | 35 | 3 | ||
| CJMM1-630S | 630 | 400.500, 630 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-630H | 630 | 400 | 800 | 65 | 45 | 3 | ||
| Cathetan: Nalika parameter uji kanggo 400V, 6A tanpa pemanasan dibebasake | ||||||||
| 2 Karakteristik operasi pemutus wektu terbalik nalika saben kutub pelepasan arus berlebih kanggo distribusi daya diuripake bebarengan | ||||||||
| Item saka Arus Tes (I/In) | Wilayah wektu uji coba | Kahanan awal | ||||||
| Arus non-tripping 1.05In | 2 jam(n>63A),1 jam(n<63A) | Kahanan adhem | ||||||
| Arus trip 1.3In | 2 jam(n>63A),1 jam(n<63A) | Langsung wae sawise tes No. 1 | ||||||
| 3 Karakteristik operasi pemecahan wektu terbalik nalika saben kutub over- Arus sing metu kanggo proteksi motor uga diuripake bebarengan. | ||||||||
| Nyetel Wektu Konvensional Saiki Kahanan Awal | Cathetan | |||||||
| 1.0Ing | >2 jam | Kahanan Adhem | ||||||
| 1.2In | ≤2 jam | Ditindakake langsung sawise tes No.1 | ||||||
| 1.5In | ≤4 menit | Kahanan Adhem | 10≤Ing≤225 | |||||
| ≤8 menit | Kahanan Adhem | 225≤Ing≤630 | ||||||
| 7.2In | 4s≤T≤10s | Kahanan Adhem | 10≤Ing≤225 | |||||
| 6s≤T≤20s | Kahanan Adhem | 225≤Ing≤630 | ||||||
| 4 Karakteristik operasi sesaat saka pemutus sirkuit kanggo distribusi daya kudu disetel minangka 10in + 20%, lan karakteristik pemutus sirkuit kanggo proteksi motor kudu disetel minangka 12ln ± 20% |
CJMM1-63, 100, 225, Ukuran Garis Besar lan Pemasangan (Sambungan papan ngarep)
| Ukuran (mm) | Kode Model | |||||||
| CJMM1-63S | CJMM1-63H | CJMM1-63S | CJMM1-100S | CJMM1-100H | CJMM1-225S | CJMM1-225 | ||
| Ukuran Garis Besar | C | 85.0 | 85.0 | 88.0 | 88.0 | 102.0 | 102.0 | |
| E | 50.0 | 50.0 | 51.0 | 51.0 | 60.0 | 52.0 | ||
| F | 23.0 | 23.0 | 23.0 | 22.5 | 25.0 | 23.5 | ||
| G | 14.0 | 14.0 | 17.5 | 17.5 | 17.0 | 17.0 | ||
| G1 | 6.5 | 6.5 | 6.5 | 6.5 | 11.5 | 11.5 | ||
| H | 73.0 | 81.0 | 68.0 | 86.0 | 88.0 | 103.0 | ||
| H1 | 90.0 | 98.5 | 86.0 | 104.0 | 110.0 | 127.0 | ||
| H2 | 18.5 | 27.0 | 24.0 | 24.0 | 24.0 | 24.0 | ||
| H3 | 4.0 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | ||
| H4 | 7.0 | 7.0 | 7.0 | 7.0 | 5.0 | 5.0 | ||
| L | 135.0 | 135.0 | 150.0 | 150.0 | 165.0 | 165.0 | ||
| L1 | 170.0 | 173.0 | 225.0 | 225.0 | 360.0 | 360.0 | ||
| L2 | 117.0 | 117.0 | 136.0 | 136.0 | 144.0 | 144.0 | ||
| W | 78.0 | 78.0 | 91.0 | 91.0 | 106.0 | 106.0 | ||
| W1 | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | ||
| W2 | - | 100.0 | - | 120.0 | - | 142.0 | ||
| W3 | - | - | 65.0 | 65.0 | 75.0 | 75.0 | ||
| Ukuran Instalasi | A | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | |
| B | 117.0 | 117.0 | 128.0 | 128.0 | 125.0 | 125.0 | ||
| od | 3.5 | 3.5 | 4.5 | 4.5 | 5.5 | 5.5 | ||
CJMM1-400,630,800, Ukuran Garis Besar lan Instalasi (Sambungan papan ngarep)
| Ukuran (mm) | Kode Model | |||||||
| CJMM1-400S | CJMM1-630S | |||||||
| Ukuran Garis Besar | C | 127 | 134 | |||||
| C1 | 173 | 184 | ||||||
| E | 89 | 89 | ||||||
| F | 65 | 65 | ||||||
| G | 26 | 29 | ||||||
| G1 | 13.5 | 14 | ||||||
| H | 107 | 111 | ||||||
| H1 | 150 | 162 | ||||||
| H2 | 39 | 44 | ||||||
| H3 | 6 | 6.5 | ||||||
| H4 | 5 | 7.5 | ||||||
| H5 | 4.5 | 4.5 | ||||||
| L | 257 | 271 | ||||||
| L1 | 465 | 475 | ||||||
| L2 | 225 | 234 | ||||||
| W | 150 | 183 | ||||||
| W1 | 48 | 58 | ||||||
| W2 | 198 | 240 | ||||||
| A | 44 | 58 | ||||||
| Ukuran Instalasi | A1 | 48 | 58 | |||||
| B | 194 | 200 | ||||||
| Od | 8 | 7 | ||||||
Diagram Pemotongan Sambungan Papan Mburi Colokke
| Ukuran (mm) | Kode Model | ||||||
| CJMM1-63S CJMM1-63H | CJMM1-100S CJMM1-100H | CJMM1-225S CJMM1-225H | CJMM1-400S | CJMM1-400H | CJMM1-630S CJMM1-630H | ||
| Ukuran Tipe Plug-in Koneksi Backboard | A | 25 | 30 | 35 | 44 | 44 | 58 |
| od | 3.5 | 4.5*6 bolongan jero | 3.3 | 7 | 7 | 7 | |
| od1 | - | - | - | 12.5 | 12.5 | 16.5 | |
| od2 | 6 | 8 | 8 | 8.5 | 9 | 8.5 | |
| oD | 8 | 24 | 26 | 31 | 33 | 37 | |
| oD1 | 8 | 16 | 20 | 33 | 37 | 37 | |
| H6 | 44 | 68 | 66 | 60 | 65 | 65 | |
| H7 | 66 | 108 | 110 | 120 | 120 | 125 | |
| H8 | 28 | 51 | 51 | 61 | 60 | 60 | |
| H9 | 38 | 65.5 | 72 | - | 83.5 | 93 | |
| H10 | 44 | 78 | 91 | 99 | 106.5 | 112 | |
| H11 | 8.5 | 17.5 | 17.5 | 22 | 21 | 21 | |
| L2 | 117 | 136 | 144 | 225 | 225 | 234 | |
| L3 | 117 | 108 | 124 | 194 | 194 | 200 | |
| L4 | 97 | 95 | 9 | 165 | 163 | 165 | |
| L5 | 138 | 180 | 190 | 285 | 285 | 302 | |
| L6 | 80 | 95 | 110 | 145 | 155 | 185 | |
| M | M6 | M8 | M10 | - | - | - | |
| K | 50.2 | 60 | 70 | 60 | 60 | 100 | |
| J | 60.7 | 62 | 54 | 129 | 129 | 123 | |
| M1 | M5 | M8 | M8 | M10 | M10 | M12 | |
| W1 | 25 | 35 | 35 | 44 | 44 | 58 | |
Pemutus sirkuit kasus sing dibentuk minangka piranti proteksi listrik sing dirancang kanggo nglindhungi sirkuit listrik saka arus sing berlebihan. Arus sing berlebihan iki bisa disebabake amarga kelebihan beban utawa korsleting. Pemutus sirkuit kasus sing dibentuk bisa digunakake ing macem-macem voltase lan frekuensi kanthi wates ngisor lan ndhuwur sing wis ditemtokake kanggo setelan trip sing bisa diatur. Saliyane mekanisme tripping, MCCB uga bisa digunakake minangka saklar pemutusan manual yen ana operasi darurat utawa pangopènan. MCCB distandardisasi lan diuji kanggo arus luwih, lonjakan voltase, lan proteksi gangguan kanggo njamin operasi sing aman ing kabeh lingkungan lan aplikasi. Iki bisa digunakake kanthi efektif minangka saklar reset kanggo sirkuit listrik kanggo medhot daya lan nyuda kerusakan sing disebabake dening kelebihan beban sirkuit, gangguan ground, korsleting, utawa nalika arus ngluwihi watesan arus.
Aplikasi MCCB wis ngowahi cara proteksi sirkuit kanthi lengkap. MCCB nuduhake pemutus sirkuit kasus plastik, sing digunakake sacara wiyar ing macem-macem industri amarga kinerja lan keandalan sing apik banget. Artikel iki bakal njelajah macem-macem aplikasi MCCB lan kepiye carane bisa duwe pengaruh sing signifikan marang keamanan listrik.
MCCB digunakake sacara wiyar ing lingkungan industri ing ngendi proteksi sirkuit penting banget. Pemutus sirkuit iki dirancang kanggo nangani arus dhuwur lan menehi proteksi sing bisa dipercaya saka kelebihan beban, korsleting, lan gangguan listrik liyane. Salah sawijining kaluwihan utama MCCB yaiku kemampuane kanggo ngganggu aliran listrik kanthi otomatis yen ana gangguan, saengga nyegah bebaya potensial kayata geni utawa kerusakan peralatan sing larang.
Ing bangunan komersial, MCCB digunakake kanggo nglindhungi sirkuit sing ngdaya sistem lampu, sistem HVAC, lan peralatan penting liyane. Pemutus sirkuit iki njamin yen ana kesalahan, bagean sirkuit sing kena pengaruh bakal dipedhot tanpa ngganggu daya menyang bangunan liyane. Kemampuan kanggo milih isolasi sirkuit sing rusak iki ngirit wektu lan nyegah downtime sing ora perlu ing saindenging fasilitas.
Aplikasi penting liyane saka MCCB yaiku ing bidang energi terbarukan. Amarga panjaluk energi ijo terus mundhak, pemutus sirkuit kasus sing dibentuk nduweni peran penting kanggo nglindhungi sistem listrik pembangkit listrik tenaga surya lan turbin angin. Pemutus sirkuit iki njamin yen listrik sing diasilake ditransfer kanthi aman menyang jaringan tanpa nyebabake kerusakan ing peralatan utawa personel.
Amarga konstruksine sing kuwat lan kinerja sing bisa dipercaya, pemutus sirkuit kasus cetakan uga akeh digunakake ing industri minyak lan gas. MCCB tanggung jawab kanggo perlindungan sirkuit ing macem-macem aplikasi kalebu platform lepas pantai, kilang, lan instalasi pipa. Pemutus sirkuit iki dirancang kanggo tahan kahanan lingkungan sing ekstrem, njamin operasi sistem listrik kritis sing terus aman.
MCCB uga wis mlebu ing bidang perumahan kanggo nyedhiyakake solusi sing efisien lan dipercaya kanggo proteksi sirkuit omah. Amarga jumlah peralatan lan sistem ing omah saya tambah, risiko kegagalan listrik uga saya tambah. MCCB nglindhungi sirkuit perumahan saka kelebihan beban lan korsleting, menehi ketenangan pikiran kanggo para pemilik omah lan nambah keamanan listrik.
Kajaba iku, MCCB digunakake sacara wiyar ing pusat data kanggo nglindhungi peralatan lan sistem penting sing ndhukung infrastruktur teknologi informasi. Pemutus sirkuit iki penting banget kanggo nyegah mundhut data amarga kesalahan listrik, njamin operasi sing ora kaganggu, lan nglindhungi informasi penting sing disimpen ing server lan peralatan jaringan liyane.
Ringkesane, pemutus sirkuit kasus cetakan digunakake ing macem-macem industri lan sektor, dadi bagean penting saka proteksi sirkuit. Kemampuane kanggo nangani arus dhuwur, ngganggu aliran arus nalika gangguan, lan konstruksi sing kuwat ndadekake pilihan sing populer kanggo njamin keamanan listrik. Apa iku ing setelan industri, bangunan komersial, instalasi energi terbarukan, fasilitas minyak lan gas, omah utawa pusat data, MCCB wis kabukten dadi solusi sing dipercaya lan efisien. Nalika teknologi terus maju, aplikasi lan pentinge pemutus sirkuit kasus cetakan mung bakal saya tambah, luwih ningkatake proteksi lan keamanan listrik ing macem-macem bidang.