• 1920x300 nybjtp

Produsen Cina CJMM1-250L/4300 160A 35/25kA MCCB Listrik Pemutus sirkuit kasus cetakan

Katrangan Cekak:

Aplikasi

Pemutus sirkuit kasus cetakan seri CJMM1 (sabanjure diarani pemutus sirkuit) bisa ditrapake kanggo sirkuit jaringan distribusi daya AC 50/60HZ kanthi voltase insulasi terukur 800V, voltase operasi terukur 690V lan arus operasi terukur saka 10A nganti 630A, digunakake kanggo nyebarake daya lan nyegah sirkuit lan peralatan catu daya saka kerusakan amarga kelebihan beban, korsleting, voltase kurang, lan kesalahan liyane, uga digunakake kanggo miwiti motor sing jarang uga kelebihan beban, korsleting, lan proteksi voltase kurang. Pemutus sirkuit iki nduweni kaluwihan volume cilik, kapasitas putus dhuwur, lengkungan pendek (utawa noarcing) lsp., bisa dilengkapi aksesoris kaya kontak alarm, pelepasan shunt, kontak tambahan lsp., iki minangka produk sing ideal kanggo pangguna. Pemutus sirkuit arus sisa bisa dipasang kanthi vertikal (instalasi vertikal) utawa dipasang kanthi horisontal (instalasi horisontal). Produk kasebut sesuai karo standar IEC60947-2 lan Gb140482.


Rincian Produk

Tag Produk

Model Produk

CJ:Kode perusahaan
M: Pemutus sirkuit kasus cetakan
1: Desain No
□: Arus sing dirating saka pigura
□: Kode karakteristik kapasitas pemecah/S nuduhake jinis standar (S bisa diilangi) H nuduhake jinis sing luwih dhuwur

Cathetan: Ana patang jinis kutub netral (kutub N) kanggo produk patang fase. Kutub netral tipe A ora dilengkapi elemen tripping arus berlebih, tansah diuripake, lan ora diuripake utawa dipateni bebarengan karo telung kutub liyane.
Kutub netral tipe B ora dilengkapi elemen tripping arus berlebih, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni). Kutub netral tipe C dilengkapi elemen tripping arus berlebih, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni). Kutub netral tipe D dilengkapi elemen tripping arus berlebih, mesthi diuripake lan ora diuripake utawa dipateni bebarengan karo telung kutub liyane.

Tabel 1

Jeneng aksesoris Rilis elektronik Pelepasan senyawa
Kontak bantu, ing ngisor voltase rilis, kontak alam 287 378
Rong set kontak bantu, kontak alarm 268 368
Pelepasan shunt, kontak alarm, kontak bantu 238 348
Ing ngisor voltase rilis, kontak alarm 248 338
Kontak bantu kontak alarm 228 328
Kontak alarm pelepasan shunt 218 318
Kontak bantu sing ora bisa dilepasake voltasene 270 370
Rong set kontak bantu 260 360
Pelepasan shunt ing ngisor voltase 250 350
Kontak bantu pelepasan shunt 240 340
Pelepasan voltase kurang 230 330
Kontak bantu 220 320
Pelepasan shunt 210 310
Kontak alarm 208 308
Ora ana aksesoris 200 300

Klasifikasi

  • Miturut kapasitas pemecahan: a jinis standar (tipe S) b jinis kapasitas pemecahan sing luwih dhuwur (tipe H)
  • Miturut mode sambungan: a sambungan papan ngarep, b sambungan papan mburi, c jinis plugin
  • Miturut mode operasi: a operasi gagang langsung, b operasi gagang rotasi, c operasi listrik
  • Miturut cacahing kutub: 1P, 2P, 3P, 4P
  • Miturut aksesoris: kontak alarm, kontak bantu, pelepasan shunt, pelepasan voltase ing ngisor

Kondisi Layanan Normal

  • Ketinggian lokasi instalasi ora kena ngluwihi 2000m
  • Suhu udara sekitar
  • Suhu udara sekitar ora kena ngluwihi +40℃
  • Nilai rata-rata ora bakal ngluwihi +35℃ sajrone 24 jam
  • Suhu udara sekitar ora kena kurang saka -5℃
  • Kahanan atmosfer:
  • 1. Kelembapan atmosfer ing kene ora kena ngluwihi 50% ing suhu paling dhuwur +40℃, lan bisa uga luwih dhuwur ing suhu sing luwih endhek, nalika suhu rata-rata paling endhek ing sasi paling teles ora ngluwihi 25℃ bisa nganti 90%, kondensasi ing permukaan produk amarga owah-owahan suhu kudu digatekake.
  • Tingkat polusi iku kelas 3

Parameter Teknis Utama

1 Nilai sing dirating saka pemutus sirkuit
Model Imax (A) Spesifikasi (A) Tegangan Operasi sing Dirating (V) Tegangan Isolasi sing Dirating (V) Icu (kA) Ic (kA) Cacahing Kutub (P) Jarak Lengkung (mm)
CJMM1-63S 63 6,10,16,20
25,32,40,
50,63
400 500 10* 5* 3 ≤50
CJMM1-63H 63 400 500 15* 10* 3,4
CJMM1-100S 100 16,20,25,32
40,50,63,
80.100
690 800 35/10 22/5 3 ≤50
CJMM1-100H 100 400 800 50 35 2,3,4
CJMM1-225S 225 100,125,
160,180,
200.225
690 800 35/10 25/5 3 ≤50
CJMM1-225H 225 400 800 50 35 2,3,4
CJMM1-400S 400 225.250,
315.350,
400
690 800 50/15 35/8 3,4 ≤100
CJMM1-400H 400 400 800 65 35 3
CJMM1-630S 630 400.500,
630
690 800 50/15 35/8 3,4 ≤100
CJMM1-630H 630 400 800 65 45 3
Cathetan: Nalika parameter uji kanggo 400V, 6A tanpa pemanasan dibebasake
2 Karakteristik operasi pemutus wektu terbalik nalika saben kutub pelepasan arus berlebih kanggo distribusi daya diuripake bebarengan
Item saka Arus Tes (I/In) Wilayah wektu uji coba Kahanan awal
Arus non-tripping 1.05In 2 jam(n>63A),1 jam(n<63A) Kahanan adhem
Arus trip 1.3In 2 jam(n>63A),1 jam(n<63A) Langsung wae
sawise tes No. 1
3 Karakteristik operasi pemecahan wektu terbalik nalika saben kutub over-
Arus sing metu kanggo proteksi motor uga diuripake bebarengan.
Nyetel Wektu Konvensional Saiki Kahanan Awal Cathetan
1.0Ing >2 jam Kahanan Adhem
1.2In ≤2 jam Ditindakake langsung sawise tes No.1
1.5In ≤4 menit Kahanan Adhem 10≤Ing≤225
≤8 menit Kahanan Adhem 225≤Ing≤630
7.2In 4s≤T≤10s Kahanan Adhem 10≤Ing≤225
6s≤T≤20s Kahanan Adhem 225≤Ing≤630
4 Karakteristik operasi sesaat saka pemutus sirkuit kanggo distribusi daya kudu disetel minangka 10in + 20%, lan karakteristik pemutus sirkuit kanggo proteksi motor kudu disetel minangka 12ln ± 20%

Ukuran Instalasi Garis Besar

CJMM1-63, 100, 225, Ukuran Garis Besar lan Pemasangan (Sambungan papan ngarep)

Ukuran (mm) Kode Model
CJMM1-63S CJMM1-63H CJMM1-63S CJMM1-100S CJMM1-100H CJMM1-225S CJMM1-225
Ukuran Garis Besar C 85.0 85.0 88.0 88.0 102.0 102.0
E 50.0 50.0 51.0 51.0 60.0 52.0
F 23.0 23.0 23.0 22.5 25.0 23.5
G 14.0 14.0 17.5 17.5 17.0 17.0
G1 6.5 6.5 6.5 6.5 11.5 11.5
H 73.0 81.0 68.0 86.0 88.0 103.0
H1 90.0 98.5 86.0 104.0 110.0 127.0
H2 18.5 27.0 24.0 24.0 24.0 24.0
H3 4.0 4.5 4.0 4.0 4.0 4.0
H4 7.0 7.0 7.0 7.0 5.0 5.0
L 135.0 135.0 150.0 150.0 165.0 165.0
L1 170.0 173.0 225.0 225.0 360.0 360.0
L2 117.0 117.0 136.0 136.0 144.0 144.0
W 78.0 78.0 91.0 91.0 106.0 106.0
W1 25.0 25.0 30.0 30.0 35.0 35.0
W2 - 100.0 - 120.0 - 142.0
W3 - - 65.0 65.0 75.0 75.0
Ukuran Instalasi A 25.0 25.0 30.0 30.0 35.0 35.0
B 117.0 117.0 128.0 128.0 125.0 125.0
od 3.5 3.5 4.5 4.5 5.5 5.5

CJMM1-400,630,800, Ukuran Garis Besar lan Instalasi (Sambungan papan ngarep)

Ukuran (mm) Kode Model
CJMM1-400S CJMM1-630S
Ukuran Garis Besar C 127 134
C1 173 184
E 89 89
F 65 65
G 26 29
G1 13.5 14
H 107 111
H1 150 162
H2 39 44
H3 6 6.5
H4 5 7.5
H5 4.5 4.5
L 257 271
L1 465 475
L2 225 234
W 150 183
W1 48 58
W2 198 240
A 44 58
Ukuran Instalasi A1 48 58
B 194 200
Od 8 7

Diagram Pemotongan Sambungan Papan Mburi Colokke

Ukuran (mm) Kode Model
CJMM1-63S
CJMM1-63H
CJMM1-100S
CJMM1-100H
CJMM1-225S
CJMM1-225H
CJMM1-400S CJMM1-400H CJMM1-630S
CJMM1-630H
Ukuran Tipe Plug-in Koneksi Backboard A 25 30 35 44 44 58
od 3.5 4.5*6
bolongan jero
3.3 7 7 7
od1 - - - 12.5 12.5 16.5
od2 6 8 8 8.5 9 8.5
oD 8 24 26 31 33 37
oD1 8 16 20 33 37 37
H6 44 68 66 60 65 65
H7 66 108 110 120 120 125
H8 28 51 51 61 60 60
H9 38 65.5 72 - 83.5 93
H10 44 78 91 99 106.5 112
H11 8.5 17.5 17.5 22 21 21
L2 117 136 144 225 225 234
L3 117 108 124 194 194 200
L4 97 95 9 165 163 165
L5 138 180 190 285 285 302
L6 80 95 110 145 155 185
M M6 M8 M10 - - -
K 50.2 60 70 60 60 100
J 60.7 62 54 129 129 123
M1 M5 M8 M8 M10 M10 M12
W1 25 35 35 44 44 58

Apa kuwi MCCB?

Pemutus sirkuit kasus sing dibentuk minangka piranti proteksi listrik sing dirancang kanggo nglindhungi sirkuit listrik saka arus sing berlebihan. Arus sing berlebihan iki bisa disebabake amarga kelebihan beban utawa korsleting. Pemutus sirkuit kasus sing dibentuk bisa digunakake ing macem-macem voltase lan frekuensi kanthi wates ngisor lan ndhuwur sing wis ditemtokake kanggo setelan trip sing bisa diatur. Saliyane mekanisme tripping, MCCB uga bisa digunakake minangka saklar pemutusan manual yen ana operasi darurat utawa pangopènan. MCCB distandardisasi lan diuji kanggo arus luwih, lonjakan voltase, lan proteksi gangguan kanggo njamin operasi sing aman ing kabeh lingkungan lan aplikasi. Iki bisa digunakake kanthi efektif minangka saklar reset kanggo sirkuit listrik kanggo medhot daya lan nyuda kerusakan sing disebabake dening kelebihan beban sirkuit, gangguan ground, korsleting, utawa nalika arus ngluwihi watesan arus.

 

Aplikasi

Aplikasi MCCB wis ngowahi cara proteksi sirkuit kanthi lengkap. MCCB nuduhake pemutus sirkuit kasus plastik, sing digunakake sacara wiyar ing macem-macem industri amarga kinerja lan keandalan sing apik banget. Artikel iki bakal njelajah macem-macem aplikasi MCCB lan kepiye carane bisa duwe pengaruh sing signifikan marang keamanan listrik.

MCCB digunakake sacara wiyar ing lingkungan industri ing ngendi proteksi sirkuit penting banget. Pemutus sirkuit iki dirancang kanggo nangani arus dhuwur lan menehi proteksi sing bisa dipercaya saka kelebihan beban, korsleting, lan gangguan listrik liyane. Salah sawijining kaluwihan utama MCCB yaiku kemampuane kanggo ngganggu aliran listrik kanthi otomatis yen ana gangguan, saengga nyegah bebaya potensial kayata geni utawa kerusakan peralatan sing larang.

Ing bangunan komersial, MCCB digunakake kanggo nglindhungi sirkuit sing ngdaya sistem lampu, sistem HVAC, lan peralatan penting liyane. Pemutus sirkuit iki njamin yen ana kesalahan, bagean sirkuit sing kena pengaruh bakal dipedhot tanpa ngganggu daya menyang bangunan liyane. Kemampuan kanggo milih isolasi sirkuit sing rusak iki ngirit wektu lan nyegah downtime sing ora perlu ing saindenging fasilitas.

Aplikasi penting liyane saka MCCB yaiku ing bidang energi terbarukan. Amarga panjaluk energi ijo terus mundhak, pemutus sirkuit kasus sing dibentuk nduweni peran penting kanggo nglindhungi sistem listrik pembangkit listrik tenaga surya lan turbin angin. Pemutus sirkuit iki njamin yen listrik sing diasilake ditransfer kanthi aman menyang jaringan tanpa nyebabake kerusakan ing peralatan utawa personel.

Amarga konstruksine sing kuwat lan kinerja sing bisa dipercaya, pemutus sirkuit kasus cetakan uga akeh digunakake ing industri minyak lan gas. MCCB tanggung jawab kanggo perlindungan sirkuit ing macem-macem aplikasi kalebu platform lepas pantai, kilang, lan instalasi pipa. Pemutus sirkuit iki dirancang kanggo tahan kahanan lingkungan sing ekstrem, njamin operasi sistem listrik kritis sing terus aman.

MCCB uga wis mlebu ing bidang perumahan kanggo nyedhiyakake solusi sing efisien lan dipercaya kanggo proteksi sirkuit omah. Amarga jumlah peralatan lan sistem ing omah saya tambah, risiko kegagalan listrik uga saya tambah. MCCB nglindhungi sirkuit perumahan saka kelebihan beban lan korsleting, menehi ketenangan pikiran kanggo para pemilik omah lan nambah keamanan listrik.

Kajaba iku, MCCB digunakake sacara wiyar ing pusat data kanggo nglindhungi peralatan lan sistem penting sing ndhukung infrastruktur teknologi informasi. Pemutus sirkuit iki penting banget kanggo nyegah mundhut data amarga kesalahan listrik, njamin operasi sing ora kaganggu, lan nglindhungi informasi penting sing disimpen ing server lan peralatan jaringan liyane.

Ringkesane, pemutus sirkuit kasus cetakan digunakake ing macem-macem industri lan sektor, dadi bagean penting saka proteksi sirkuit. Kemampuane kanggo nangani arus dhuwur, ngganggu aliran arus nalika gangguan, lan konstruksi sing kuwat ndadekake pilihan sing populer kanggo njamin keamanan listrik. Apa iku ing setelan industri, bangunan komersial, instalasi energi terbarukan, fasilitas minyak lan gas, omah utawa pusat data, MCCB wis kabukten dadi solusi sing dipercaya lan efisien. Nalika teknologi terus maju, aplikasi lan pentinge pemutus sirkuit kasus cetakan mung bakal saya tambah, luwih ningkatake proteksi lan keamanan listrik ing macem-macem bidang.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesenmu ing kene lan kirim menyang kita