CJ: Kode perusahaan
M: Moulded kasus sirkuit breaker
1: Desain No
□: Rated saiki pigura
□:Kode karakteristik kapasitas break/S nuduhake jinis standar (S bisa diilangi)H nuduhake jinis sing luwih dhuwur
Cathetan: Ana patang jinis kutub netral (kutub N) kanggo produk patang fase. Kutub netral saka jinis A ora dilengkapi unsur tripping over-current, tansah diuripake, lan ora diuripake utawa dipateni bebarengan karo liyane. telung cagak.
Kutub netral saka tipe B ora dilengkapi unsur tripping arus liwat, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni) Kutub netral saka tipe C dilengkapi over- unsur tripping saiki, lan diuripake utawa dipateni bebarengan karo telung kutub liyane (kutub netral diuripake sadurunge dipateni) Kutub netral jinis D dilengkapi unsur tripping arus liwat, tansah diuripake lan ora diuripake. ing utawa mati bebarengan karo telung kutub liyane.
Jeneng aksesori | Rilis elektronik | release senyawa | ||||||
Kontak tambahan, ing release voltase, kontak alam | 287 | 378 | ||||||
Loro set kontak tambahan, kontak weker | 268 | 368 | ||||||
Shunt release, kontak weker, kontak tambahan | 238 | 348 | ||||||
Ing release voltase, kontak weker | 248 | 338 | ||||||
Kontak bantu kontak alarm | 228 | 328 | ||||||
Shunt release kontak weker | 218 | 318 | ||||||
Release kurang voltase kontak tambahan | 270 | 370 | ||||||
Loro set kontak tambahan | 260 | 360 | ||||||
Shunt release under-voltage release | 250 | 350 | ||||||
Shunt release kontak tambahan | 240 | 340 | ||||||
Ing release voltase | 230 | 330 | ||||||
Kontak bantu | 220 | 320 | ||||||
Rilis shunt | 210 | 310 | ||||||
Kontak weker | 208 | 308 | ||||||
Ora ana aksesoris | 200 | 300 |
1 Nilai rated saka mbobol sirkuit | ||||||||
Model | Imax (A) | Spesifikasi (A) | Rated Tegangan Operasi (V) | Rated Insulation Voltage (V) | Icu (kA) | IC (kA) | Jumlah Kutub (P) | Jarak Busur (mm) |
CJMM1-63S | 63 | 6,10,16,20 25,32,40, 50,63 | 400 | 500 | 10* | 5* | 3 | ≤50 |
CJMM1-63H | 63 | 400 | 500 | 15* | 10* | 3,4 | ||
CJMM1-100S | 100 | 16,20,25,32 40,50,63, 80.100 | 690 | 800 | 35/10 | 22/5 | 3 | ≤50 |
CJMM1-100H | 100 | 400 | 800 | 50 | 35 | 2,3,4 | ||
CJMM1-225S | 225 | 100.125, 160.180, 200.225 | 690 | 800 | 35/10 | 25/5 | 3 | ≤50 |
CJMM1-225H | 225 | 400 | 800 | 50 | 35 | 2,3,4 | ||
CJMM1-400S | 400 | 225.250, 315.350, 400 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
CJMM1-400H | 400 | 400 | 800 | 65 | 35 | 3 | ||
CJMM1-630S | 630 | 400.500, 630 | 690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
CJMM1-630H | 630 | 400 | 800 | 65 | 45 | 3 | ||
Cathetan: Nalika paramèter test kanggo 400V, 6A tanpa release panas |
2 Karakteristik operasi pemutus wektu kuwalik nalika saben kutub pelepasan arus luwih kanggo distribusi daya diuripake bebarengan | ||||||||
Item tes Saiki (I/In) | Area wektu tes | negara wiwitan | ||||||
Arus non-tripping 1.05In | 2h(n>63A),1h(n<63A) | kahanan kadhemen | ||||||
Arus tripping 1.3 In | 2h(n>63A),1h(n<63A) | Langsung nerusake sawise test No.1 |
3 Karakteristik operasi breaking wektu kuwalik nalika saben kutub over- release saiki kanggo pangayoman motor powered ing wektu sing padha. | ||||||||
Nyetel Wektu Konvensional Saiki Negara Awal | Cathetan | |||||||
1.0 Ing | > 2 jam | Negara Kadhemen | ||||||
1.2 Ing | ≤2 jam | Diterusake langsung sawise tes No.1 | ||||||
1.5 Ing | ≤4min | Negara Kadhemen | 10≤In≤225 | |||||
≤8 min | Negara Kadhemen | 225≤Ing≤630 | ||||||
7.2 Ing | 4s≤T≤10s | Negara Kadhemen | 10≤In≤225 | |||||
6s≤T≤20s | Negara Kadhemen | 225≤Ing≤630 |
4 Karakteristik operasi cepet saka pemutus sirkuit kanggo distribusi daya kudu disetel minangka 10in + 20%, lan siji pemutus sirkuit kanggo proteksi motor kudu disetel minangka 12ln±20% |
CJMM1-63, 100, 225, Outline lan Ukuran Instalasi (Sambungan papan ngarep)
Ukuran (mm) | Kode Model | |||||||
CJMM1-63S | CJMM1-63H | CJMM1-63S | CJMM1-100S | CJMM1-100H | CJMM1-225S | CJMM1-225 | ||
Ukuran Outline | C | 85.0 | 85.0 | 88.0 | 88.0 | 102.0 | 102.0 | |
E | 50.0 | 50.0 | 51.0 | 51.0 | 60.0 | 52.0 | ||
F | 23.0 | 23.0 | 23.0 | 22.5 | 25.0 | 23.5 | ||
G | 14.0 | 14.0 | 17.5 | 17.5 | 17.0 | 17.0 | ||
G1 | 6.5 | 6.5 | 6.5 | 6.5 | 11.5 | 11.5 | ||
H | 73.0 | 81.0 | 68.0 | 86.0 | 88.0 | 103.0 | ||
H1 | 90.0 | 98.5 | 86.0 | 104.0 | 110.0 | 127.0 | ||
H2 | 18.5 | 27.0 | 24.0 | 24.0 | 24.0 | 24.0 | ||
H3 | 4.0 | 4.5 | 4.0 | 4.0 | 4.0 | 4.0 | ||
H4 | 7.0 | 7.0 | 7.0 | 7.0 | 5.0 | 5.0 | ||
L | 135.0 | 135.0 | 150.0 | 150.0 | 165.0 | 165.0 | ||
L1 | 170.0 | 173.0 | 225.0 | 225.0 | 360.0 | 360.0 | ||
L2 | 117.0 | 117.0 | 136.0 | 136.0 | 144.0 | 144.0 | ||
W | 78.0 | 78.0 | 91.0 | 91.0 | 106.0 | 106.0 | ||
W1 | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | ||
W2 | - | 100.0 | - | 120.0 | - | 142.0 | ||
W3 | - | - | 65.0 | 65.0 | 75.0 | 75.0 | ||
Instal Ukuran | A | 25.0 | 25.0 | 30.0 | 30.0 | 35.0 | 35.0 | |
B | 117.0 | 117.0 | 128.0 | 128.0 | 125.0 | 125.0 | ||
od | 3.5 | 3.5 | 4.5 | 4.5 | 5.5 | 5.5 |
CJMM1-400,630,800, Outline lan Ukuran Instalasi (Sambungan papan ngarep)
Ukuran (mm) | Kode Model | |||||||
CJMM1-400S | CJMM1-630S | |||||||
Ukuran Outline | C | 127 | 134 | |||||
C1 | 173 | 184 | ||||||
E | 89 | 89 | ||||||
F | 65 | 65 | ||||||
G | 26 | 29 | ||||||
G1 | 13.5 | 14 | ||||||
H | 107 | 111 | ||||||
H1 | 150 | 162 | ||||||
H2 | 39 | 44 | ||||||
H3 | 6 | 6.5 | ||||||
H4 | 5 | 7.5 | ||||||
H5 | 4.5 | 4.5 | ||||||
L | 257 | 271 | ||||||
L1 | 465 | 475 | ||||||
L2 | 225 | 234 | ||||||
W | 150 | 183 | ||||||
W1 | 48 | 58 | ||||||
W2 | 198 | 240 | ||||||
A | 44 | 58 | ||||||
Instal Ukuran | A1 | 48 | 58 | |||||
B | 194 | 200 | ||||||
Od | 8 | 7 |
Diagram Cut-out Sambungan Papan mburi Plug In
Ukuran (mm) | Kode Model | ||||||
CJMM1-63S CJMM1-63H | CJMM1-100S CJMM1-100H | CJMM1-225S CJMM1-225H | CJMM1-400S | CJMM1-400H | CJMM1-630S CJMM1-630H | ||
Ukuran saka Back Board Connection Tipe Plug ing | A | 25 | 30 | 35 | 44 | 44 | 58 |
od | 3.5 | 4.5*6 bolongan jero | 3.3 | 7 | 7 | 7 | |
od1 | - | - | - | 12.5 | 12.5 | 16.5 | |
od2 | 6 | 8 | 8 | 8.5 | 9 | 8.5 | |
oD | 8 | 24 | 26 | 31 | 33 | 37 | |
oD1 | 8 | 16 | 20 | 33 | 37 | 37 | |
H6 | 44 | 68 | 66 | 60 | 65 | 65 | |
H7 | 66 | 108 | 110 | 120 | 120 | 125 | |
H8 | 28 | 51 | 51 | 61 | 60 | 60 | |
H9 | 38 | 65.5 | 72 | - | 83.5 | 93 | |
H10 | 44 | 78 | 91 | 99 | 106.5 | 112 | |
H11 | 8.5 | 17.5 | 17.5 | 22 | 21 | 21 | |
L2 | 117 | 136 | 144 | 225 | 225 | 234 | |
L3 | 117 | 108 | 124 | 194 | 194 | 200 | |
L4 | 97 | 95 | 9 | 165 | 163 | 165 | |
L5 | 138 | 180 | 190 | 285 | 285 | 302 | |
L6 | 80 | 95 | 110 | 145 | 155 | 185 | |
M | M6 | M8 | M10 | - | - | - | |
K | 50.2 | 60 | 70 | 60 | 60 | 100 | |
J | 60.7 | 62 | 54 | 129 | 129 | 123 | |
M1 | M5 | M8 | M8 | M10 | M10 | M12 | |
W1 | 25 | 35 | 35 | 44 | 44 | 58 |
Pemutus sirkuit kasus cetakan minangka piranti proteksi listrik sing dirancang kanggo nglindhungi sirkuit listrik saka arus sing berlebihan.Arus gedhe iki bisa disebabake amarga kakehan utawa sirkuit cendhak.Pemutus sirkuit cilik sing dicetak bisa digunakake ing macem-macem voltase lan frekuensi kanthi watesan setelan trip sing bisa diatur ing ngisor lan ndhuwur.Saliyane mekanisme tripping, MCCB uga bisa digunakake minangka switch pedhot manual yen ana operasi darurat utawa pangopènan.MCCBs standar lan dites kanggo overcurrent, mundhak voltase, lan pangayoman fault kanggo mesthekake operasi aman ing kabeh lingkungan lan aplikasi.Padha bisa èfèktif minangka ngalih reset kanggo sirkuit listrik kanggo medhot daya lan nyilikake karusakan disebabake kakehan sirkuit, fault lemah, sirkuit cendhak, utawa nalika saiki ngluwihi watesan saiki.
Aplikasi molded case circuit breaker (MCCBs) ing macem-macem industri wis ngowahi cara sistem listrik.MCCB minangka komponen penting kanggo njamin operasi sirkuit sing aman lan efisien.Padha nyedhiyani pangayoman marang overloads, short circuits, lan faults electrical liyane, kang penting kanggo nyegah kacilakan listrik lan beboyo geni.
Salah sawijining kaluwihan utama MCCB yaiku kemampuan kanggo nangani arus sing dhuwur.Iki dirancang khusus kanggo nglindhungi lan ngontrol sirkuit kanthi panjaluk energi sing dhuwur.Industri kayata manufaktur, pertambangan, minyak lan gas, lan transportasi gumantung banget marang MCCB kanggo nglindhungi peralatan lan infrastruktur listrik sing kritis.Kemampuan MCCBs kanggo efisien nangani arus dhuwur lan kanthi otomatis medhot daya ing acara kakehan utawa Gagal ndadekake MCCBs indispensable ing industri iki.
Kauntungan liyane sing penting saka MCCB yaiku instalasi lan panggunaan sing gampang.Padha kompak ing ukuran lan bisa gampang Integrasi menyang switchboards lan switchboards.Desain modular ngidini konfigurasi fleksibel, supaya bisa adaptasi karo syarat instalasi sing beda.Kajaba iku, MCCBs kasedhiya ing sawetara saka sudhut dirating saiki, mesthekake kompatibilitas karo macem-macem kathah electrical.Gampang instalasi lan nggunakake ndadekake MCCBs pilihan populer kanggo instalasi anyar lan retrofits kanggo sistem electrical ana.
Akurasi lan linuwih MCCB nduweni peran penting kanggo njamin operasi sistem listrik tanpa gangguan.MCCBs duwe mekanisme trip majeng sing kanthi ndeteksi lan nanggapi bentet electrical.Dheweke dilengkapi macem-macem jinis sensor lan sensor kayata termal, magnetik, elektronik, lan sapiturute, sing bisa ngerteni kahanan listrik sing ora normal.Sawise fault dideteksi, MCCB lelungan lan langsung medhot daya, nyegah karusakan luwih.
MCCB uga mbantu ningkatake efisiensi energi sakabèhé sistem listrik.Kanthi èfèktif nglindhungi Gagal listrik lan overloads, padha nyegah panas banget lan sampah rasah saka listrik.Iki ora mung nyuda resiko karusakan peralatan, nanging uga ngoptimalake konsumsi energi.Kanthi penekanan sing saya tambah akeh babagan hemat energi lan pembangunan sing lestari, aplikasi pemutus sirkuit kasus cetakan penting kanggo njamin operasi sing efisien lan ramah lingkungan ing macem-macem industri.
Singkatnya, aplikasi sing akeh saka pemutus sirkuit kasus cetakan wis ningkatake safety, linuwih lan efisiensi sistem listrik ing macem-macem industri.Kemampuan kanggo nangani arus sing dhuwur, gampang dipasang, deteksi kesalahan sing tepat, lan kontribusi kanggo efisiensi energi nggawe komponen sing penting kanggo proteksi lan kontrol listrik.Nalika teknologi maju, pemutus sirkuit kasus cetakan terus berkembang kanggo nyukupi panjaluk sistem listrik modern sing saya tambah akeh.Minangka industri terus gumantung ing elektrifikasi kanggo operate, peran MCCB ing mesthekake operasi aman lan efisien sirkuit mung bakal dadi luwih penting.