Data Teknis
| IEC Listrik | | | 150 | 275 | 320 |
| Tegangan AC Nominal (50/60Hz) | | Uc/Un | 120V | 230V | 230V |
| Tegangan Operasi Terus-menerus Maksimum (AC) | (LN) | Uc | 150V | 270V | 320V |
| (N-PE) | Uc | 255V |
| Arus Debit Nominal (8/20μs) | (LN)/(N-PE) | In | 20 kA/50 kA |
| Arus Debit Maksimum (8/20μs) | (LN)/(N-PE) | Imax | 50 kA/100 kA |
| Arus Pembuangan Impuls (10/350μs) | (LN)/(N-PE) | Iimp | 12.5kA/50kA |
| Energi Spesifik | (LN)/(N-PE) | W/R | 39 kJ/Ω / 625 kJ/Ω |
| Ngisi daya | (LN)/(N-PE) | Q | 6.25 As/12.5As |
| Tingkat Proteksi Tegangan | (LN)/(N-PE) | Up | 1.0kV/1.5kV | 1,5 kV/1,5 kV | 1. 6kV/1.5 kV |
| (N-PE) | Ifi | 100 SENJATA |
| Wektu Respon | (LN)/(N-PE) | tA | <25ns/<100ns |
| Sekring Cadangan (maks) | | | 315A/250A gG |
| Rating Arus Sirkuit Pendek (AC) | (LN) | ISCCR | 25kA/50kA |
| TOV Tahan 5 detik | (LN) | UT | 180V | 335V | 335V |
| TOV 120 menit | (LN) | UT | 230V | 440V | 440V |
| | mode | Gagal Aman | Gagal Aman | Gagal Aman |
| TOV Tahan 200ms | (N-PE) | UT | 1200V |
| UL Listrik | | | | | |
| Tegangan Operasi Terus Maksimum (AC) | | MCOV | 150V/255V | 275V/255V | 320V/255V |
| Rating Proteksi Tegangan | | VPR (Veteran Nasional) | 600V/1200V | 900V/1200V | 1200V/1200V |
| Arus Debit Nominal (8/20μs) | | In | 20kA/20kA | 20kA/20kA | 20kA/20kA |
| Rating Arus Sirkuit Pendek (AC) | | SCCR (Kode Pos) | 200kA | 150kA | 150kA |

Sadurunge: Piranti Proteksi Lonjakan SPD Surya Seri PV CJ-12.5 1.8kv SPD DC Sabanjure: Piranti Proteksi Lonjakan Kutub Tunggal CJ-B25 2p 1.8kv sing Bisa Dipasang SPD