Seri CRS-200,350 minangka sumber daya sing disegel output grup tunggal 200,350W, kanthi desain profil rendah 30mm, nggunakake 85 ~ 264VAC input ac lengkap kabeh seri kanggo nyedhiyakake output 5V,12V,15V,24V,36V lan 48V.
Jinis | Indikator teknis | |||||
Output | voltase DC | 5V | 12V | 24V | 36V | 48V |
Rated saiki | 40A | 17A | 8.8A | 5.9A | 4.4A | |
daya dirating | 200W | 204W | 211.2W | 212.4W | 211.2W | |
Ripple lan gangguan | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Range pangaturan voltase | ± 10% | |||||
Presisi voltase | ± 3,0% | ± 1,5% | ± 1,0% | ± 1,0% | ± 1,0% | |
tingkat imbuhan linear | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
Tingkat rregulation beban | ± 2,0% | ± 1,0% | ± 0,5% | ± 0,5% | ± 0,5% | |
Wektu lintang | 1500ms, 50ms/230VAC 1500ms,50ms/115VAC (beban lengkap) | |||||
Jaga wektu | 16ms/230VAC 12ms/115VA (beban penuh) | |||||
Input | Range voltase / frekuensi | 90-132VAC/180-264VAC liwat pilihan switch/240-370VDC 47Hz-63Hz | ||||
Efisiensi (khas) | 87% | 88% | 90% | 89,50% | 90% | |
Arus kerja | 4A / 115VAC 2.2A / 230VAC | |||||
Arus kejut | wiwitan kadhemen: 60A / 115VAC 60A / 230VAC | |||||
Arus bocor | <2mA 240VAC | |||||
Karakteristik pangayoman | Proteksi kakehan | Jinis pangayoman: mode burp, mbusak kahanan ora normal lan kanthi otomatis bali menyang normal | ||||
pangayoman overvoltage | Jinis pangayoman: nutup output lan miwiti maneh kanthi otomatis normal | |||||
Proteksi suhu liwat | Jinis pangayoman: nutup output lan miwiti maneh kanthi otomatis normal | |||||
Ilmu lingkungan | Suhu lan kelembapan kerja | -25 ℃ ~ + 70 ℃; 20% ~ 90RH | ||||
Suhu panyimpenan lan kelembapan | 40 ℃ ~ + 85 ℃;10%~95RH | |||||
Keamanan | Resistance tekanan | Input - output: 3KVAC input-case: 2KVAC output -case: 0.5kvac durasi: 1 menit | ||||
impedansi insulasi | Input – output lan input – shell, output – shell: 500 VDC /100 m Ω 25 ℃, 70% RH | |||||
Liyane | Ukuran | 215 * 115 * 30mm (L * W * H) | ||||
Bobot net / bobot reged | 660g/727g | |||||
pangandikan | (1) Pangukuran riak lan gangguan: Nggunakake 12 "garis pasangan bengkong kanthi kapasitor 0.1uF lan 47uF kanthi paralel ing terminal, pangukuran ditindakake kanthi bandwidth 20MHz. (2) Efisiensi dites ing voltase input 230VAC, dirating mbukak lan 25 ℃ suhu sekitar. Akurasi: kalebu kesalahan setelan, tingkat imbuhan linear lan tingkat adjustmient mbukak. Cara tes tingkat imbuhan linear: testing saka voltase kurang kanggo voltase dhuwur ing Dirating loadLoad cara test tingkat imbuhan: saka 0% -100% dirating load.The wiwitan-up wektu diukur ing negara wiwitan kadhemen, lan mesin ngalih cepet Kerep bisa nambah wektu wiwitan.Yen dhuwure ndhuwur 2000 meter, ing suhu operasi kudu sudo dening 5/1000. |