| Output | Tipe | MS-1000-12 | MS-1000-24 | MS-1000-36 | MS-1000-48 | MS-1000-70 |
| Tegangan DC | 12V | 24V | 36V | 48V | 70V | |
| Arus sing Dirating | 83.3A | 41.7A | 27.8A | 20.8A | 14.3A | |
| Rentang Saiki | 0~83.3A | 0~41.7A | 0~27.8A | 0~20.8A | 0~14.3A | |
| Daya sing Dirating | 999.6W | 1000.8W | 1000.8W | 998.4W | 1000.1W | |
| Riak & Swara (cathetan maksimal 2) | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
| Rentang Penyesuaian Tegangan | 5-13.5V | 5-27.5V | 5-40V | 5-56V | 5-73V | |
| Cathetan Toleransi Tegangan.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Tingkat Regulasi Linear | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
| Tingkat Pengaturan Beban | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
| Persiapan, Wektu Munggah | 200ms, 50ms, 20ms: 230VAC | |||||
| Masukan | Rentang Tegangan | 180-264VAC (Dipilih nganggo saklar, 110V utawa 220V) | ||||
| Rentang Frekuensi | 47~63Hz | |||||
| Efisiensi (Tipe.) | 85% | |||||
| Arus AC (Tipe) | 10A/230VAC | |||||
| Arus Masuk (Tipe) | 35A/115VAC 55A/230VAC | |||||
| Arus Bocor | <2.5mA/240VAC | |||||
| Proteksi | Kakehan beban | Daya output sing dirating 105%-135% | ||||
| Mode pangayoman: mateni output lan mulihake sawise miwiti maneh | ||||||
| Lingkungan | Suhu lan kelembapan kerja | -20~+50°C; 20~90%RH,Ora kondensasi | ||||
| Suhu lan kelembapan panyimpenan | -20~+85°C, 10~95% RH | |||||
| Koefisien Suhu | ±0,03%7°C (0~50°C) | |||||
| Tahan getaran | 10~500Hz, 2G10 menit/siklus, sumbu X, Y lan Z saben 60 menit; Instalasi: miturut IEC60068-2-6 | |||||
| Keamanan | Peraturan keamanan | GB 4943.1-2011 | ||||
| Resistensi insulasi | IP-O/P, I/P-FG,O/P-FG:100M Ohm / 500VDC/25°C/70% RH | |||||
| Emisi kompatibilitas elektromagnetik | GB 17625.1-2012 | |||||
| Kekebalan kompatibilitas elektromagnetik | Standar industri abot GB/T 9254-2008 Kelas A | |||||
| Liyane | MTBF | ≥364.6K jam.MIL-HDBK-217F (25°C) | ||||
| Ukuran | 240*124*65mm (P*L*T) | |||||
| Paket | 1.7Kg; 10pcs/17Kg | |||||
| Cathetan | (1) Kajaba ditemtokake liya, Kabeh parameter spesifikasi dilebokake minangka 230VAC, Uji beban sing dirating digawe ing suhu lingkungan 25°C. (2) Cara pangukuran riak lan gangguan: Gunakake kabel bengkong 12”, Ing wektu sing padha, terminal kudu disambungake sacara paralel karo kapasitor 0.1uf lan 47uf, Pangukuran ditindakake ing bandwidth 20MHZ. (3) Akurasi: Kalebu kesalahan setelan, tingkat pangaturan linier lan tingkat pangaturan beban. (4) Catu daya dianggep minangka bagean saka komponen ing sistem lan kudu diverifikasi kompatibilitas elektromagnetik bebarengan karo peralatan terminal. | |||||