| Tipe | Indikator teknis | ||||||
| Output | Tegangan DC | 5V | 12V | 18V | 24V | 36V | 48V |
| Arus sing dirating | 50A | 29A | 19.4A | 14.5A | 9.7A | 7.3A | |
| Daya sing dirating | 250W | 350W | 350W | 350W | 350W | 350.4W | |
| Riak lan swara | <150mVp-p | <150mVp-p | <150mVp-p | <150mVp-p | <240mVp-p | <240mVp-p | |
| Rentang pengaturan tegangan | ±10% | ||||||
| Presisi voltase | ±2.0% | ±1.0% | |||||
| Tingkat pangaturan linier | ±1% | ||||||
| Tingkat regulasi beban | <±1.5% | <±1.2% | <±1.2% | <±1% | <±0,5% | <±0,5% | |
| Masukan | Rentang/frekuensi voltase | 90-132VAC/180-264VAC 47Hz-63Hz (254VDC~370VDC) | |||||
| Efisiensi (biasane) | >74% | >82% | >82% | >84% | >86% | >86% | |
| Arus kerja/Arus kejut | <5.2A 115VAC; <2.8A 230VAC | ||||||
| Arus kejut | 110VAC 25A, 220AC:50A | ||||||
| Wektu miwiti | 200ms, 50ms, 20ms; 220VAC | ||||||
| Karakteristik pangayoman | Proteksi kelebihan beban | ≥105%-150%; Output arus konstan +VO mudhun menyang titik tekanan ngisor, output cut off direset: daya maneh | |||||
| Proteksi overvoltage | ≥115%-145% Nutup output | ||||||
| Proteksi kurang voltase | ≤10%-45% Nutup output | ||||||
| Proteksi sirkuit cendhak | Tutup output | ||||||
| Proteksi saka panas banget | Pateni output (mode proteksi: mateni output lan miwiti kanthi otomatis nalika suhu bali normal) | ||||||
| Ilmu lingkungan | Suhu lan kelembapan kerja | -10ºC~+50ºC;20%~90RH | |||||
| Suhu lan kelembapan panyimpenan | -20ºC~+85ºC; 10%~95RH | ||||||
| Keamanan | Resistensi tekanan | Input – output :1.5KVAC input-case :1.5KVAC output -case: 0.5kvac durasi :1 menit | |||||
| arus bocor | Input-output 1.5KVAC <5mA | ||||||
| arus bocor | Input-output 220VAC <1mA | ||||||
| Impedansi insulasi | Input-output lan input-shell, output-shell: 500 VDC/100mΩ | ||||||
| Liyane | Ukuran | 215*114*50mm (P * L * T) | |||||
| Bobot bersih / bobot kotor | 874.1g/936.3g | ||||||
| Cathetan | (1) Pangukuran riak lan gangguan: Nggunakake jalur pasangan bengkong 12 “kanthi kapasitor 0.1uF lan 47uF paralel ing terminal, pangukuran ditindakake ing bandwidth 20MHz. | ||||||
| (2) Efisiensi diuji ing voltase input 230VAC, beban terukur lan suhu sekitar 25ºC. Akurasi: kalebu kesalahan setelan, laju penyesuaian linier lan laju penyesuaian beban. Cara uji laju penyesuaian linier: uji saka voltase endhek nganti voltase dhuwur ing beban terukur. Cara uji laju penyesuaian beban: saka beban terukur 0%-100%. Wektu wiwitan diukur ing kahanan wiwitan adhem, lan mesin saklar sing kerep cepet bisa nambah wektu wiwitan. Nalika dhuwure luwih saka 2000 meter, suhu operasi kudu dikurangi 5/1000. | |||||||