| Model | CJMM6RT/A-125 | CJMM6RT-160 | CJMM6RT-250 | ||||||||||
| Arus pigura mlebu | 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, | 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 140A, 160A | 100A, 125A, 140A, 160A, 180A, 200A, 225A, 250A | ||||||||||
| Pedhot sirkuit cendhak kode kapasitas | C | S | M | H | C | S | M | H | C | S | M | H | |
| Cacahing tiang | 3P/4P | ||||||||||||
| Dirating kerjane Tegangan Ue (V), AC | AC400V | ||||||||||||
| Insulasi sing dirating voltase Ui (V) | 1000V | ||||||||||||
| Tahan impuls sing dirating Tegangan Uimp (kV) | 8kV | ||||||||||||
| Layanan sing dirating korsleting kapasitas pemecahan Ics (%Icu) | AC 400V | 5kA | 10kA | 18kA | 50kA | 5kA | 10kA | 10kA | 50kA | 5kA | 8kA | 10kA | 50kA |
| Dirating paling apik korsleting kapasitas pemecahan Icu (kA) | 10kA | 20kA | 36kA | 50kA | 8kA | 20kA | 20kA | 50kA | 8kA | 15kA | 20kA | 50kA | |
| Kategori selektif | Kelas A | ||||||||||||
| Tipe pelepasan arus berlebih | Tipe termomagnetik | ||||||||||||
| Garis besar CJMM6RT dimensi (mm) Amba (L) * Dawa (P)*Dhuwur (T) | Arus pigura | CJMM6RT/A-125 | CJMM6RT-160 | CJMM6RT-250 | |||||||||
| Cacahing tiang | 3P | 4P | 3P | 4P | 3P | 4P | |||||||
| Jembar | 75 | 100 | 90 | 120 | 105 | 140 | |||||||
| Dawane | 130 | 130 | 155 | 155 | 165 | 165 | |||||||
| Dhuwur/tutup rai | 68 | 68 | 68 | 82 | 68 | 82 | 68 | 88 | 68 | 88 | |||
| Dhuwur/gagang | 94.5 | 94.5 | 94 | 108 | 94 | 108 | 96 | 116 | 96 | 116 | |||
| Model | CJMM6RT-400 | CJMM6RT-630 | CJMM6RT-800 | CJMM6RT-1250 | CJMM6RT-2000 | ||||||
| Arus pigura mlebu | 320A, 350A, 400A | 400A, 500A, 630A | 630A, 700A, 800A | 1000A, 1250A | 1600A | ||||||
| Pedhot sirkuit cendhak kode kapasitas | M | H | M | H | M | H | M | H | M | H | |
| Cacahing tiang | |||||||||||
| Dirating kerjane Tegangan Ue (V), AC | |||||||||||
| Insulasi sing dirating voltase Ui (V) | |||||||||||
| Tahan impuls sing dirating Tegangan Uimp (kV) | |||||||||||
| Layanan sing dirating korsleting kapasitas pemecahan Ics (%Icu) | AC 400V | 50kA | 50kA | 50kA | 50kA | 50kA | 65kA | 50kA | 65kA | 50kA | 85kA |
| Dirating paling apik korsleting kapasitas pemecahan Icu (kA) | 50kA | 50kA | 50kA | 50kA | 65kA | 85kA | 65kA | 85kA | 50kA | 100kA | |
| Kategori selektif | |||||||||||
| Tipe pelepasan arus berlebih | |||||||||||
| Garis besar CJMM6RT dimensi (mm) Amba (L) * Dawa (P)*Dhuwur (T) | Arus pigura | CJMM6RT-400 | CJMM6RT-630 | CJMM6RT-800 | CJMM6RT-1250 | CJMM6RT-2000 | |||||
| Cacahing tiang | 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | 3P | 4P | |
| Jembar | 140 | 184 | 140 | 184 | 210 | 280 | 210 | 280 | 210 | 280 | |
| Dawane | 257 | 257 | 257 | 257 | 275.5 | 275.5 | 275.5 | 275.5 | 340 | 340 | |
| Dhuwur/tutup rai | 103 | 103 | 103 | 103 | 103 | 103 | 103 | 103 | 141 | 141 | |
| Dhuwur/gagang | 152 | 152 | 152 | 152 | 152 | 152 | 152 | 152 | 244 | 244 | |
Cathetan: Dhuwure saka ngisor dasar nganti (penutup rai/gagang)
| NO | Ing (A) | Parameter | Syarat indeks |
| 1 | 160-1250 | Arus setelan tripping overload tunda suwe (A) | 0.7~1.0ln bisa diatur (opsional) |
| 2 | 0.8~1.0ln bisa diatur (opsional) | ||
| 3 | Arus setelan tripping sesaat sirkuit pendek (A) | 5ln~10ln bisa diatur (opsional) | |
| 4 | Proteksi sirkuit cendhak | Nalika 0.8*(5ln/10ln), ora bakal bisa digunakake sajrone 0.2 detik | |
| 5 | Nalika 1.2*(5ln/10ln), iki bakal bisa digunakake sajrone 0.2s | ||
| 6 | 125 | Arus setelan tripping overload tunda suwe (A) | 0.7~1.0ln bisa diatur (opsional) |
| 7 | 0.8~1.0ln bisa diatur (opsional) |