| Tipe | NDR-480 | ||
| Output | Tegangan DC/Arus Terukur | 24V/20A | 48V/10A |
| Rentang Saiki | 0 ~ 20A | 0 ~ 10A | |
| Daya sing Dirating | 480W | 480W | |
| Riak & Swara | 150mVp-p | 150mVp-p | |
| Wilayah Votage DC | 24 ~ 28V | 48 ~ 55V | |
| akurasi voltase | ± 1 .0% | ± 1 .0% | |
| tingkat pangaturan linier | ± 0,5% | ± 0,5% | |
| Regulasi Beban | ± 1 .0% | ± 1 .0% | |
| Wektu miwiti lan munggah | 1500ms, 100ms/230VAC 3000ms, 100ms/ 115VAC (BEBAN PENUH) | ||
| Wektu panyimpenan (Tipe.) | 16ms/230VAC | ||
| Masukan | Rentang voltase | 180 ~ 264VAC | |
| Rentang Frekuensi | 47 ~ 63Hz | ||
| Efisiensi (Tipe.) | 88% | ||
| Arus AC (Tipe) | 2.4A/230VAC | ||
| Arus Lonjakan (Tipe) | 35A/230VAC | ||
| Arus Bocor | <2mA/240VAC | ||
| Karakteristik pangayoman | Beban sing Keluwih | Daya output sing dirating 105% ~ 130% | |
| Pateni voltase output, lan pulih kanthi otomatis sawise beban kahanan abnormal diilangi. | |||
| Volasi sing berlebihan | 29 ~ 33V | 56 ~ 65V | |
| Pateni output lan pulihake output normal sawise daya diuripake maneh. | |||
| Ilmu lingkungan | Suhu sing berlebihan | Pateni output lan pulihake output normal sawise daya diuripake maneh. | |
| Suhu kerja | -20~+70°C | ||
| Kelembapan operasi | 20 ~ 95% Kaki Kiri, | ||
| Suhu/kelembapan panyimpenan | -40 ~ +85C, 10 ~ 95% RH | ||
| Koefisien suhu | ±0,03%/°C (0~50°C) | ||
| Tahan getaran | 10 ~ 500Hz, 2G 10 Menit/Siklus, X, Y, Z 60 Menit kanggo saben, Instalasi miturut IEC60068-2-6 | ||
| Keamanan lan elektromagnetik kompatibilitas | Spesifikasi Keamanan | GB 4943.1-2011 | |
| Tahan Tegangan | I/PO/P:1.5KVAC I/P-FG:1.5VAC O/P-FG:0.5KVAC | ||
| Resistensi insulasi | IP-O/P, I/P-FG,O/P-FG:100M Ohm / 500VDC/25°C/70% RH | ||
| Emisi kompatibilitas elektromagnetik | Sesuai karo GB 17625.1-2012 | ||
| Kekebalan kompatibilitas elektromagnetik | Sesuai karo GB/T 9254-2008 Grade A saka standar industri abot | ||
| Ukuran/Paket | 85,5*125,2*128,5mm (P*L*T)/ 1,5Kg; 8 pcs/ 13Kg/0,9CUFT | ||
| Cathetan | (1) Kajaba ditemtokake liya, Kabeh parameter spesifikasi dilebokake minangka 230VAC, Uji beban sing dirating digawe ing suhu lingkungan 25°C. (2) Cara pangukuran riak lan gangguan: Gunakake kabel bengkong 12”, Ing wektu sing padha, terminal kudu disambungake sacara paralel karo kapasitor 0.1uf lan 47uf, Pangukuran ditindakake ing bandwidth 20MHZ. (3) Akurasi: Kalebu kesalahan setelan, tingkat pangaturan linier lan tingkat pangaturan beban. (4) Jarak instalasi: Nalika daya lengkap diisi permanen, jarak sing disaranake yaiku 40mm saka ndhuwur, 20mm saka ngisor, lan 5mm saka sisih kiwa lan tengen. Yen peralatan sing jejer minangka sumber panas, jarak ruang sing disaranake yaiku 15mm. (5) Nalika dhuwure ngluwihi 2000m (6500ft), suhu sekitar model tanpa kipas mudhun kanthi rasio 3.5C/1000m, lan model tanpa kipas mudhun kanthi rasio 5C/1000m. | ||